Use to weather proof the penetration of vent pipe through the roof. Fits up to 7⁄12 roof pitch. Storm Collar required. Made of malliable dead soft aluminum.

Overview of CVS® Concentric Venting System

An economical venting solution for condensing and noncondensing appliances, the Concentric Venting System (CVS) features a UL1738 approved super-ferritic stainless steel inner wall. The proprietary twist-lock connection eliminates use of clamps or mechanical fasteners and saves installation time. Only one penetration is needed through the roof or the wall for both exhaust and combustion air. Multiple pipe lengths and telescoping pipe extensions eliminate field cutting of pipe. CVS is the only concentric vent system to incorporate o-rings on the inner wall and outer casing to prevent exhaust or combustion air leakage. Custom adapters are available to transition from co-linear to coaxial venting systems. The built-in condensate management system prevents standing condensation. The Concentric Venting System is a fully sealed, gas tight system to deliver superior performance with the heating unit.

Details

SKU: 35CVS-DSA

Applications

Concentric Venting System (CVS) (direct vent or two-pipe system) for use with condensing natural gas or propane Categories II, III and IV appliances or Canada’s Type BH Gas Vent Systems, (having a maximum rated operating temperature of 500°F). For use with Stoves and inserts of Type L gas, pellet, oil, corn and biofuel (Rated to a continuous use flue temperature up to 570°F). CVS can be used on a wide range of appliances, including: gas boilers, warm air furnaces, water heaters, unit heaters, tankless water heaters, pellet stoves, direct vent gas or propane stoves, heaters, and fireplaces.

Materials and Construction

Unitized concentric construction. Inner: Laser-welded UL approved 444 super-ferritic stainless steel .012″ Outer: Laser-welded, paintable, zincalume .018″ Silicone O-ring seals on inner liner and outer wall. Precision twist-lock connection on outer wall.

Clearances

CVS is listed to 0” clearance as a double-wall vent system for Category II, III, and IV appliances, for flue temperature of up to 400°F for horizontal enclosures, and up to 480°F for vertical enclosures. CVS must maintain 1” clearance to combustibles when used with pellet fuel. When CVS is used as a concentric/direct vent system on gas, the clearance to combustibles is specified by the appliance manufacturer.

Diameters

3″ inner and 5″ outer.

Listings

CVS vent pipe is listed to UL 1738 (MH25700) as a double-wall vent system for Category II, III and IV appliances. It is pressure rated to 10 WC for the inner pipe. This product is also intended to be used as a direct vent system for Listed to UL 1738 (DGSH.MH25700) and ULC S636 (DGSH7.MH25700). Pressure rated to 10” W.C. Listed to UL 641 (DFTX.MH8381), ULC S609 (DFTX7.MH8381), and ULC/ORD 441 (DFVAC.MH21150). Listed in combination with gas appliances, has been tested and listed as a decorative gas appliance system or as a direct vent heater system. Check with your appliance manufacturer for approval.

Instructions

Typical Installation

Refer to our Typical Venting Installation drawings to select the appropriate component parts for your installation.

DuraVent Pro

More Typical Installations

DirectVent Pro installation

Installation Key 

1 Vertical Termination Cap
2 Storm Collar
3 Flashing
4 Cathedral Ceiling Support Box
5 Pipe
6 45° Elbow
7 Class A Chimney Conversion Kit
8 4″ Flex
9 90° Elbow
10 Horizontal Termination Cap
11 Snorkel Termination Cap
12 Colinear Kit
13 3″ Flex
14 Co-Axial to Co-Linear Connector
15 Masonry Chimney Conversion Kit
16 Elbow Strap

Planning Your Installation:

  1. For vertical gas stove installations, measure the height from the stove outlet to the ceiling to determine the length of black pipe required. Select a ceiling support/wall thimble cover or a cathedral ceiling support box.
  2. To determine the length of galvanized pipe required, measure the ceiling thickness and the vertical rise in an attic or second story. Firestops are required at each floor level beyond the first floor ceiling support/wall thimble cover or cathedral ceiling support box. If an offset is required to avoid obstructions, use a pair of 45° elbows. For proper support, use elbow straps with offsets. Use wall straps for long vertical runs. Attic Insulation Shield is required in attic.
  3. Measure the roof pitch. Select the proper flashing and storm collar. Determine the minimum height above the roof.
  4. For horizontal installations, check the appliance manufacturer’s instructions for minimum rise and maximum horizontal run. A snorkel termination may be used if height restrictions prevent adequate rise above the appliance. Select the appropriate Horizontal Termination Cap (see appliance manufacturer installation instructions). To protect vinyl siding, select vinyl siding standoff. Check appliance manufacturer’s instructions for wall thimble and firestop requirements.

Design Recommendations

  • The following design recommendations are general guideline to assist in the design and selection of venting components for your installation. Always follow Duravent Installation instructions enclosed with the cap or support box before installing your chimney system. Installation instructions can be viewed online at www.duravent.com, under Catalogs and Instructions. Important: Check the manufacturer’s rating plate and instruction manual to confirm that the Duravent direct vent system is approved for use on the brand name appliance you have selected.
  • The inner and outer pipe diameters should match the outlet size of the appliance.
  • Check the appliance manufacturer’s installation instructions to confirm which types of vent configurations are permitted (i.e. horizontal, vertical, chimney reline, etc.). Also, check for any venting restrictions such as maximum horizontal run, minimum and maximum vertical rise, maximum offset, etc.
  • Be fire safe! Maintain at least the minimum clearances (air-space) between the vent pipe and nearby combustibles, as specified in the appliance manufacturer’s installation instructions. Use proper support and bracing. Follow local building codes and have your venting system inspected.

Product Resources

Catalogs

Bulletins

Brochures

Sales Sheets

Educational Papers

Shipping / Freight / Return Info

 

Same-Day / 24 hour shipping

Same-Day/24 hour shipping - If we have the product in stock, we can ship
same day if ordered before 12pm Monday - Friday (CST).

Freight Claims Policy

Please follow these very important steps when it comes to Freight Items that are damaged or missing

  • Open and inspect the order while the delivery driver is present. If delivery driver does not provide sufficient time to do so, please notate the delivery receipt.
  • By signing the delivery receipt without noting any damage or missing items, you confirm that your order arrived complete and in excellent condition.
  • Record any damage or missing pieces directly on the delivery receipt.
  • Do not discard damaged item(s) or any original packaging. For severe damage, write “Refused due to damage” on the delivery receipt and contact us immediately.
  • Report any damage within two business days, including delivery details and photos showing the issue
  • Damaged item(s) must be returned within 30 days. Failure to return them will result in a charge to the original payment method.

Return Merchandise Authorization Policy

Please follow these very important steps when Returning Items. Contact our team.

  • Submit your return request within 30 days of delivery.
  • You will receive an email within 1-2 business days confirming whether your return request has been approved or denied.
  • Please also note that a 20% restocking fee may apply to approved returns
  • If approved, you will receive an itemized Return Authorization, return shipping labels (if requested), and detailed instructions within 1–2 business days
  • From the date this email is received, you will have 14 days to return the product.
  • Once our distributor receives and inspects the returned item(s), your refund will be issued within 1–2 weeks
  • Items returned outside of this process or time frame are not eligible for a refund.

Shop by Best Sellers

Fireplace

Get In Touch

Call or Text us for our Best Price

It's important to us to go above and beyond for our clients and make sure you make the right decision for your home.