Detroit Radiant DSRF Vented Two Stage Patio Tube Heater, 16 ft – DSRF-30

$2,800.80

✓ Free Shipping
✓ No Sales Tax (except WY)

✓ 100% Price Match Guarantee

Detroit Radiant Logo BlackAuthorized Dealer – Full Warranty Included

Heat Output *

65,000 BTU/h - DSRF-30-65 (+$0)
80,000 BTU/h - DSRF-30-80 (+$0)

Fuel Type *

Natural Gas (+$0)
Propane (+$0)

Accessories

Re-Verber-Ray DS-TB Closed Body Turnbuckle
3/8"-16 closed body turnbuckle for heater mounting - DS-TB (+$17.10)
Detroit Radiant DSRF Vented Two Stage Patio Tube Heater, 16 ft - DSRF-30 - Gripple tube heater hanging cable, 10' looped w/locking fastener (200 lb WLL)
Gripple tube heater hanging cable, 10' looped w/locking fastener (200 lb WLL) - THGH10-3 (+$18.90)
Re-Verber-Ray AIR-EX Air Intake Extension with Cap
Air intake extension with cap (4" dia. inlet duct, cap, screws, support cable) - AIR-EX (+$50.40)
Re-Verber-Ray DSR-EXH DSRF Exhaust Kit
DSRF exhaust kit for unvented operation (TP-883A diffuser + TP-884A access panel) - DSR-EXH (+$61.20)
21"–32" hanging bracket kit, 2 hanging points (replaces included DSR-HANG) - DS-BKT20-2 (+$160.20)
34"–45" hanging bracket kit, 2 hanging points (replaces included DSR-HANG) - DS-BKT33-2 (+$167.40)

Controls

Detroit Radiant Single Knob Infrared Patio Heater Controller
Two-Stage Controller, 1 Knob (1 zone) - TH-DSTS1: 1 knob, 1 zone, high/low for two stage heaters (+$148.50)
Detroit Radiant Dual Knob Infrared Patio Heater Controller
Two-Stage Controller, 2 Knobs (2 zones) - TH-DSTS2: 2 knobs, 2 zones, high/low for two stage heaters (+$244.80)
Detroit Radiant Toggle Switch and 4-Hour Timer Controller
Two-Stage Controller, Toggle Switch + 4-Hour Timer - TH-T2-4H: High/low toggle with a 4-hour shutoff timer; transformer built in (+$292.50)
Detroit Radiant WEP-TS Weatherproof Timer Enclosure
Weatherproof Timer Enclosure Package - WEP-TS: Lockable outdoor box with a 4-hour timer and on/off switch (+$127.80)
Detroit Radiant TH-200 Two Stage Rain-Tight Thermostat
Rain-Tight Thermostat, Two Stage - TH-200: Weatherproof, 30 to 110 F, high/low for two stage heaters (+$130.50)
Detroit Radiant ERK External Relay Kit
External Relay Kit (1 per heater) - ERK: Needed on each heater when several share one control; standard locations (+$46.80)
Detroit Radiant ERK-HE External Relay Kit for Wet Locations
External Relay Kit, Wet Locations (1 per heater) - ERK-HE: Needed on each heater when several share one control; sealed for wet spots (+$82.80)
Detroit Radiant 4000-01V 40 VA Transformer
40 VA Transformer, 120 V to 24 V - 4000-01V: 120 V to 24 V; runs up to 2 DSC heaters or one thermostat (+$52.20)
Detroit Radiant Re-Verber-Ray TH-T2-4H-NT
Two-Stage Toggle + 4-Hour Timer, No Transformer (1 heater) - TH-T2-4H-NT: High/low toggle with 4-hour timer, no transformer; one tube heater only (+$292.50)
Detroit Radiant Re-Verber-Ray TH-DSP2Z
Premium 2-Zone Controller with Timer - TH-DSP2Z: Lit buttons for 2 zones with a 30 min, 1 or 2 hour timer (+$616.50)
Detroit Radiant Re-Verber-Ray TH-DSP3Z
Premium 3-Zone Controller with Timer - TH-DSP3Z: Lit buttons for 3 zones with a 30 min, 1 or 2 hour timer (+$697.50)
Detroit Radiant Re-Verber-Ray TH-PC
Premium Touch-Screen Controller (BACnet / Modbus) - TH-PC: Touch screen with BACnet, Modbus and Zigbee for building systems (+$945)
Detroit Radiant Re-Verber-Ray SWPD60
60-Minute Twist Timer - SWPD60: Twist timer, up to 60 minutes (+$66.60)
Detroit Radiant Re-Verber-Ray SWPD-4H
4-Hour Twist Timer - SWPD-4H: Twist timer, up to 4 hours (+$66.60)
Detroit Radiant Re-Verber-Ray TH-109
Rain-Tight Thermostat, Two Stage (40–100°F) - TH-109: Weatherproof, 40 to 100 F, high/low for two stage heaters (+$175.50)
Detroit Radiant Re-Verber-Ray TH-BR12
Digital Thermostat, Non-Programmable - TH-BR12: Digital, non programmable, 45 to 90 F; 24 V, needs a transformer (+$79.20)
Detroit Radiant Re-Verber-Ray TH-BR22
Digital Thermostat, Programmable - TH-BR22: Digital, programmable, 45 to 90 F; 24 V, needs a transformer (+$100.80)
Detroit Radiant Re-Verber-Ray TH-BR42
Digital Thermostat, Programmable + Remote Sensing - TH-BR42: Programmable with remote sensor port; 24 V, needs a transformer (+$180)
Detroit Radiant Re-Verber-Ray TH-1F86WF
Wi-Fi Programmable Thermostat - TH-1F86WF: Wi-Fi, set from your phone; 24 V, needs a transformer (+$262.80)
Detroit Radiant Re-Verber-Ray TH-B205WF
Wi-Fi Programmable Thermostat (Braeburn) - TH-B205WF: Wi-Fi, set from your phone; 24 V, needs a transformer (+$189)
Detroit Radiant Re-Verber-Ray TH-ENASC
NEMA 4X Wi-Fi Thermostat with App Scheduling - TH-ENASC: Outdoor rated Wi-Fi with app scheduling; 24 V, needs a transformer (+$387)
Detroit Radiant Re-Verber-Ray TH-B500WL
Wireless Thermostat Kit - TH-B500WL: Wireless thermostat kit, no wire to the heater; 24 V (+$280.80)
Detroit Radiant Re-Verber-Ray MTGRD
Locking Thermostat Guard, Metal - MTGRD: Metal cover with key, stops tampering (+$45)
Detroit Radiant Re-Verber-Ray F29GRD
Locking Thermostat Guard, Clear - F29GRD: Clear cover with key, stops tampering (+$46.80)
Product price: $2,800.80
Total options:
Order total:

Detroit Radiant DSRF-30 Vented Tube Heater: overhead patio heat with exhaust that can vent outside

The Detroit Radiant DSRF-30 Vented Tube Heater is a gas heater for covered patios. Its black coated tubes are steel coated with aluminum. It is 16 feet 4 inches long, weighs 170 pounds, and hangs from a ceiling or canopy 9 to 16 feet high. It runs on a piped gas line, natural gas or propane, so there is no tank to refill. Detroit Radiant Products is a family owned company founded in 1955 that builds its heaters in Warren, Michigan.

Radiant heat warms people and surfaces directly, like sunshine, instead of warming the air, so it works outdoors. It warms about 26 by 12 feet. Exhaust can be ducted outside rather than drifting under the canopy. Choose 65,000 BTUs (50,000 on low) or 80,000 BTUs (52,000 on low), plus your gas type. It drops to low once the patio warms. Warranty coverage is three years on components, five on tubes, and ten on the burner. Need more length? See the Detroit Radiant DSRF-35 Vented Tube Heater. The Detroit Radiant DSRF-30 Vented Tube Heater ships free from My Cozy Outdoors with No Sales Tax (except WY) and the full manufacturer warranty.

Weight 77.1 kg
Dimensions 243.8 × 55.9 × 55.9 cm

Features

  • Dual certified to ANSI Z83.20 and ANSI Z83.26
  • Pre- and post-purge controls
  • Self-diagnostic LED, microprocessor based circuitry

Applications

Application by Industry

Use radiant heat in a variety of hard to heat applications. Infrared heats people, floors, walls and other surfaces directly without heating the air first, which is why it works where forced air fails. Tap an industry to see how Detroit Radiant heaters are used there.

Detroit Radiant Re-Verber-Ray infrared heaters in a agriculture application
Detroit Radiant Re-Verber-Ray infrared heaters in a agriculture application
Detroit Radiant Re-Verber-Ray infrared heaters in a agriculture application
Detroit Radiant Re-Verber-Ray infrared heaters in a agriculture application
Detroit Radiant Re-Verber-Ray infrared heaters in a agriculture application
Detroit Radiant Re-Verber-Ray infrared heaters in a agriculture application

Agriculture

Low intensity radiant tube brooders and high intensity brooders.

Infrared heaters are widely used in swine, poultry, brooder and dairy barns because they have a long record of proven results. Two stage heaters add efficiency and several benefits: lower running costs, less on and off cycling, more fuel saved, the ability to change the heat output, and better animal comfort. The result is better animal performance, less fuel burned and a longer heater life.

  • Save 20 to 50 percent on the fuel bill with radiant tube heat compared with other heating appliances
  • Cut annual maintenance by up to 90 percent
  • Optional two stage operation for better comfort
  • Quiet, clean operation
Detroit Radiant Re-Verber-Ray infrared heaters in a aircraft hangars application
Detroit Radiant Re-Verber-Ray infrared heaters in a aircraft hangars application
Detroit Radiant Re-Verber-Ray infrared heaters in a aircraft hangars application
Detroit Radiant Re-Verber-Ray infrared heaters in a aircraft hangars application

Aircraft Hangars

Heat large, hard to heat areas.

Gas fired infrared heaters heat efficiently because they warm exactly what needs to be warm: people, floors, walls and other surfaces, instead of the air. That suits hangars with huge air volumes or lots of air movement, where warm air heating is wasted because it must first heat all the air, which rises before anything else does.

Equipment selection: high BTU tube heaters or high intensity models are made for high mounting spots like hangars. Two stage heaters recover the heat lost through the big doors, then cycle less during normal operation. Most of the heat should be concentrated near the main door with burner boxes or extra heaters. ANSI/NFPA 409 calls for the heater to sit at least 10 feet above the highest wing surface of any aircraft stored inside.

Commonly used products

  • HLV Series engineered vacuum systems
  • REV Series two stage low intensity
  • HL3 Series two stage low intensity
  • DX3L Series single stage low intensity
  • DR Series high intensity
Detroit Radiant Re-Verber-Ray infrared heaters in a automotive application
Detroit Radiant Re-Verber-Ray infrared heaters in a automotive application
Detroit Radiant Re-Verber-Ray infrared heaters in a automotive application
Detroit Radiant Re-Verber-Ray infrared heaters in a automotive application
Detroit Radiant Re-Verber-Ray infrared heaters in a automotive application
Detroit Radiant Re-Verber-Ray infrared heaters in a automotive application

Automotive

Efficiently heat open door service areas.

Most service garages and vehicle maintenance shops have a lot of open door area for their size, and cold vehicles keep rolling in. That makes infrared the economical way to heat the space. When placing heaters, keep them away from overhead doors and vehicle lifts, keep the published clearances from hose reels and exhaust collection systems, and never put a heater inside a paint booth. In smaller areas where tube heaters are not practical, a forced air unit heater can fill in.

Detroit Radiant recommends low intensity tube heaters with outside air supplied to each heater where degreasers, parts washers or rust proofing are used, plus mechanical ventilation at floor level, since most chemical fumes are heavier than air. Most centers use 75,000 to 150,000 BTU tube heaters in a perimeter layout, with extra units or burner boxes stacked at the door areas.

Commonly used products

  • REV Series two stage low intensity
  • HL3 Series two stage low intensity
  • DX3L Series single stage low intensity
  • MP3 Series modulating low intensity
  • DR Series high intensity
  • FA and UH Series separated combustion unit heaters
Detroit Radiant Re-Verber-Ray infrared heaters in a car washes application
Detroit Radiant Re-Verber-Ray infrared heaters in a car washes application
Detroit Radiant Re-Verber-Ray infrared heaters in a car washes application
Detroit Radiant Re-Verber-Ray infrared heaters in a car washes application

Car Washes

Save energy while heating harsh environments.

Short tube heaters with high BTU ratings, or small to mid size high intensity heaters, are the efficient choices for a car wash. Most car wash heating systems are designed to protect against freezing and to spot heat employees, so the heaters are best placed at the ends of the tunnel. Millivolt controls are the usual pick for equipment rooms, if shielded from the wind, so freeze protection keeps working during a power outage.

Stainless steel, silicone sealant, waterproof controls and electrical attachments are recommended, and two stage operation adds further energy savings.

Commonly used products

  • Stainless steel low intensity tube heaters
  • DR Series high intensity
Detroit Radiant Re-Verber-Ray infrared heaters in a cng facilities application
Detroit Radiant Re-Verber-Ray infrared heaters in a cng facilities application
Detroit Radiant Re-Verber-Ray infrared heaters in a cng facilities application
Detroit Radiant Re-Verber-Ray infrared heaters in a cng facilities application
Detroit Radiant Re-Verber-Ray infrared heaters in a cng facilities application

CNG Facilities

Heating vehicle maintenance facilities.

Natural gas is an affordable, abundant fuel for fleets, and Detroit Radiant has the experience to heat compressed natural gas (CNG) vehicle maintenance facilities. The company offers a range of options and can usually turn around concept drawings within a few days.

CNG shops must comply with special requirements such as NFPA 30A, which says the heater surface temperature must not exceed 750 degrees F. Detroit Radiant's CSA design certified heaters meet the construction criteria the code requires. When the space needs more burners than will fit, the engineered HLV vacuum system can be used in the design.

Commonly used products

  • CL3 Series two stage low intensity
  • CX3 Series single stage low intensity
  • HLV Series engineered vacuum systems
Detroit Radiant Re-Verber-Ray infrared heaters in a military application
Detroit Radiant Re-Verber-Ray infrared heaters in a military application
Detroit Radiant Re-Verber-Ray infrared heaters in a military application
Detroit Radiant Re-Verber-Ray infrared heaters in a military application

Military

Products and expertise for the Navy, Air Force, Army, Marines and Coast Guard.

Detroit Radiant's product range and military experience have been used in a wide variety of military applications, including projects for the United States Navy, Air Force, Army, Marines and Coast Guard.

Commonly used products

  • HLV Series engineered vacuum systems
  • MP3 Series modulating low intensity
  • REV Series two stage low intensity
  • HL3 Series two stage low intensity
  • DX3L Series single stage low intensity
Detroit Radiant Re-Verber-Ray infrared heaters in a municipal application
Detroit Radiant Re-Verber-Ray infrared heaters in a municipal application
Detroit Radiant Re-Verber-Ray infrared heaters in a municipal application

Municipal

Fleet heating for fleet, transit and police facilities.

Detroit Radiant offers a wide selection of infrared heating products for municipal fleet facilities: fleet maintenance garages, transit facilities and garages, police stations and more.

Commonly used products

  • CL3 Series two stage low intensity
  • CX3 Series single stage low intensity
  • HLV Series engineered vacuum systems
  • REV Series two stage low intensity
  • HL3 Series two stage low intensity
  • DX3L Series single stage low intensity
  • DR Series high intensity
Detroit Radiant Re-Verber-Ray infrared heaters in a outdoor application
Detroit Radiant Re-Verber-Ray infrared heaters in a outdoor application
Detroit Radiant Re-Verber-Ray infrared heaters in a outdoor application
Detroit Radiant Re-Verber-Ray infrared heaters in a outdoor application
Detroit Radiant Re-Verber-Ray infrared heaters in a outdoor application
Detroit Radiant Re-Verber-Ray infrared heaters in a outdoor application
Detroit Radiant Re-Verber-Ray infrared heaters in a outdoor application
Detroit Radiant Re-Verber-Ray infrared heaters in a outdoor application

Outdoor

Gently warm people and furnishings, not the air.

Whether you want to extend the outdoor season, heat a designated smoking area or add room for peak crowds, Detroit Radiant's range has an outdoor heater to fit.

  • Air movement: wind, even a light breeze, is the biggest variable in outdoor comfort. Barriers such as wind curtains are highly recommended wherever possible, but always keep the clearances to combustibles.
  • Mounting heights: outdoor and spot heating usually means mounting the heater lower, closer to the people. A lower mount covers less area but gives a more focused heat pattern, so the final height may need adjusting to get the result you want.
  • Your expectations: there is rarely a one size fits all answer. Maximum comfort in extreme conditions takes more heaters; taking the chill off a smoking area for a few minutes takes fewer.

Commonly used products

Detroit Radiant Re-Verber-Ray infrared heaters in a spot heating application
Detroit Radiant Re-Verber-Ray infrared heaters in a spot heating application
Detroit Radiant Re-Verber-Ray infrared heaters in a spot heating application
Detroit Radiant Re-Verber-Ray infrared heaters in a spot heating application

Spot Heating

Heating only a portion of a building? Detroit Radiant offers great options.

When only part of a building needs heat, consider spot heating. Both high intensity infrared heaters and low intensity tube heaters suit it. Tube heaters are usually placed in a U shape for spot heating: the U puts the hottest tube next to the coolest tube for even comfort and gives the most flexibility in placement.

High intensity heaters are usually easier to install and cheaper for spot heating. They are especially suited to buildings that are poorly insulated, loosely built, have high ceilings or lose a lot of heat per square foot.

Commonly used products

Detroit Radiant Re-Verber-Ray infrared heaters in a warehouses application
Detroit Radiant Re-Verber-Ray infrared heaters in a warehouses application
Detroit Radiant Re-Verber-Ray infrared heaters in a warehouses application
Detroit Radiant Re-Verber-Ray infrared heaters in a warehouses application

Warehouses

Strategically placed for the best coverage of the space.

Detroit Radiant offers many cost effective options for heating a warehouse. When choosing equipment, consider the warehouse type, its size, the mounting heights, the level of insulation and any other design features that affect the heater choice. Tube heaters give plenty of placement options with regard to clearances and are usually thermostat controlled.

Place warehouse heaters for the best coverage: a perimeter layout, or a series of heaters between rows of storage racks. Whatever the layout, mind the clearances to combustibles, especially above and below the heater where stacked goods are a concern. Detroit Radiant recommends warning plaques (part PLQ) to advise users of the clearances and stacking limits.

Commonly used products

  • HLV Series engineered vacuum systems
  • REV Series two stage low intensity
  • HL3 Series two stage low intensity
  • DX3L Series single stage low intensity
  • DR Series high intensity
  • ELD Series electric
  • ELX Series electric

The heaters we carry from Detroit Radiant are the outdoor and electric lines: the DSC, DSR and DSRF gas patio heaters and the ELD, ELX, DSS and BAH electric heaters. The commercial tube and high intensity lines named above are built by the same company for the other industries.

Shop All Detroit Radiant Heaters

Which Heater Do I Need?

Patio Heater Finder

Tell us about your outdoor space and we’ll match the right heater, and tell you how many you need.

Where will the heater go?

How do you want to mount it?

Electric or gas?

How big is the area you want to keep warm?

Just the seating area, not the whole yard. Heaters warm people and furniture below them, not the air.

×
|

Specifications

SKU: DSRF-30-65, DSRF-30-80

Specification Value
Model DSRF-30-65 / -80 — per selected Heat Output
BTU/h (High / Low) 65,000 / 50,000 · 80,000 / 52,000 (per Heat Output)
Length 16′-4″
Weight 170 lbs.
Mounting Height 9′ to 16′ (factory guideline), level or up to 30°
Clearances to Combustibles (0°) 25” side, 6” top, 60” below; see the manual for 30° mounting
Gas Type Natural Gas (3.5” W.C.) or Propane (10.0” W.C.) – specify at order
Shipping Truckline only; ships on a skid
Combustion Chamber 4” Aluminized Steel
Radiant Tubes .95 Emissive Black-Coated Aluminized Steel
Electrical 120 V, 60 Hz with power cord; 24 V controls; 4.8 A starting / 1.1 A running; hot surface ignition
Included Hanging kit and stainless steel flexible gas connector
Certification CSA certified for commercial/industrial indoor and outdoor use and residential outdoor use only (ANSI Z83.20 vented / Z83.26 unvented)
Warranty 3-5-10 (Components/Tubes/Burner)
Dimensions 195.5″ L x 18.25″ W x 11.75″ H (16 ft 4 in)
Radiant Tube 28 linear ft of 4″ tube
Shipping Weight 170 lbs boxed; Truckline only; skid adds 90 lb; 4 per skid
Shipping Boxes Burner box (1): 38 L x 24 W x 10 H in; Housing box (1): 96 L x 22 W x 22 H in; Egg crate box (1): 50 L x 16 W x 4 H in
Approximate Area Heated 26 ft x 12 ft
Clearances to Combustibles (30°) 65,000 and 80,000 BTU/h: 36″ front, 10″ behind, 12″ ends, 9″ top, 47″ below; between 0° and 30° use the larger figure

Manuals / Catalogs

Catalogs, Brochures & Data Sheets

DSRF Series Brochure

DSRF Series Full Submittal Package

Gas-Fired Patio Heater Design Guide

Designer Series Packing List

Controls Packing List

Venting Packing List

Manuals

DSRF Series Installation, Operation, Parts, & Maintenance Manual

FAQ

What does vented mean on this tube heater?

The DSRF is the vented version of Detroit Radiant’s low-intensity tube heater: its combustion products can be ducted out through a vent instead of released under the canopy, which is why the brochure recommends it for driving ranges and restaurant patios that need a vented solution. It is CSA certified for commercial indoor and outdoor use and residential outdoor use only.

How long is it and how much heat?

16 feet 4 inches of housing with 28 linear feet of radiant tube per the brochure, and a Heat Output selector of 65,000 BTU per hour with 50,000 low fire or 80,000 with 52,000 low. Natural gas or propane is chosen on the Fuel Type selector. It weighs about 170 pounds and ships by truck on a skid.

How high should it hang?

The brochure gives 9 to 16 feet mounting heights at 0 or up to 30 degrees, with clearances at 0 degrees of 25 inches to the sides, 6 inches above and 60 inches below. A hanging kit is included; the Accessories selector adds turnbuckles, Gripple cable and 2-point hanging bracket kits sized for 21 to 32 or 34 to 45 inch drops.

What power does it need?

A 120 volt, 60 Hz supply with a power cord standard and 24 volt controls; amps are 4.8 starting and 1.1 running. Ignition is hot surface, and the microprocessor circuitry runs pre- and post-purge cycles with a self-diagnostic LED, per the Features tab and brochure. A stainless flexible gas connector is included.

Can I duct the exhaust and intake?

Yes. The DSRF is certified for vented operation, and the DSRF manual linked in the Manuals tab covers the vent run, which it reserves for trained gas installation personnel. The Accessories selector adds a 4 inch air intake extension with cap; the exhaust kit listed there is the vendor’s kit for running the heater unvented instead, not venting parts. Browse other commercial patio heaters for unvented alternatives.

What is the warranty?

3 years on components, 5 on the radiant tubes and 10 on the burner, per the Specifications tab and brochure. The tubes are .95 emissive black-coated aluminized steel over a 4 inch aluminized combustion chamber, and the manual calls for an annual inspection to keep the heater in warranty.

Customer Reviews

Be the first to review this product

What Our Customers Say

Shop by Best Sellers

Fireplace

Get In Touch

Call or Text us for our Best Price

It's important to us to go above and beyond for our clients and make sure you make the right decision for your home.