DuraVent 10” DuraChimney II Customize your Kit

$0.00

✓ Free Shipping
✓ No Sales Tax (except WY)
✓ 100% Price Match Guarantee

DuraVent Logo

DuraVent Logo    Authorized Dealer – Full Warranty Included

Length of Chimney Pipe for 10" Diameter *

12" - 10DCA-12 (+$261.20)
18" - 10DCA-18 (+$201.02)
36" - 10DCA-36 (+$304.66)
48" - 10DCA-48 (+$348.64)

Elbow 10"

15° Elbow - 10DCA-E15 (+$584.27)
30° Elbow - 10DCA-E30 (+$326.64)

Build Your Chimney Kit

Elbow Strap 10" - 10DCA-ES (+$190.85)
Supplementary Support 10" - 10DCA-SS (+$300.55)
Wall Strap 10" - 10DCA-WS (+$199.45)
Stabilizer 10" - 10DCA-ST (+$125.77)
10" Diameter Anchor Plate - 10DCA-AP (+$584.27)
10" Anchor Plate w/ Damper - 10DCA-APD (+$1,305.99)
10" DCA FireStop Spacer - 10DCA-FS (+$95.80)
10" Diameter Attic Insulation Shield - 10DCA-IS (+$734.96)
10" Diameter Roof Radiation Shield - 10DCA-RRS (+$91.09)
10" Chase Top Flashing - 10DCA-CTF (+$378.05)
10" Chase Top Collar - 10DCA-CTC (+$231.83)
10" Diameter Storm Collar - 10DCA-SC (+$64.39)
Chimney Cap 10" - 10DCA-VC1 (+$526.10)
10" European Copper King Adapter - 10DCA-ECK (+$626.70)
10" European Copper Bishop Adapter - 10DCA-ECB (+$288.08)
Snow Splitter - 6DT-SP (+$283.68)
Total options:
Order total:

DuraVent DuraChimney II 10 inch Kit Builder: choose a whole chimney on one page

The DuraVent DuraChimney II 10 inch Kit Builder is a page for choosing a complete fireplace chimney, from the fireplace top to the cap. You build it here instead of shopping for each part separately. There is no starting package price. Your total comes from the parts and quantities you choose. DuraChimney II is DuraVent’s air cooled chimney, a double wall pipe in 8 to 16 inch sizes for fireplaces that burn wood, oil, coal, or gas. Match the 10 inch diameter to the fireplace’s chimney outlet, called its flue collar. The fireplace maker must approve DuraChimney II for that fireplace.

Start with at least one required pipe section, choosing lengths of 12, 18, 36, or 48 inches and quantities. Each joint reduces the assembled height by 1 inch. Add 15 or 30 degree elbows if the chimney needs to move sideways. They are sold individually, and a sideways shift takes two. Then select the supports, shields, and roof parts your chimney needs. The cap must finish 3 feet above the roof exit and 2 feet above anything within 10 feet. Need a larger diameter? See the DuraVent DuraChimney II 12 inch Kit Builder. The DuraVent DuraChimney II 10 inch Kit Builder ships free from My Cozy Outdoors with No Sales Tax (except WY) and the full manufacturer warranty.

Details

SKU: 10DCA-12

Applications

DuraChimney II is a double-wall, air-cooled chimney system for use with masonry fireplaces which burn wood, oil, coal, or gas.

Materials and Construction

.016″ 430 stainless steel inner wall and .021″ galvanized steel outer wall. For stainless steel outer wall, contact Customer Service.

Unitized pipe sections. No field assembly of inners and outers required.

Clearances

2″ clearance to combustibles.

Shrouds

UL Listed with Duravent shroud specifications.

Diameters

10″, 12″, 14″, and 16″

Listings

UL Listed to UL 103 and ULC S604 standards (MH7399).

Instructions

 

Typical Installation

Refer to our Typical Installation drawings to select the appropriate component parts for your installation.

DuraVent DuraChimney II

 

More Typical Installations

 

DuraVent More Typical Installations

Installation Key

1 Chimney Cap
2 Storm Collar
3 Chase Top Flashing
4 Roof Radiation Shield
5 Chimney Section
6 Elbow
7 Elbow Strap
8 Stabilizer
9 Firestop
10 Attic Insulation Shield
11 Anchor Plate
12 Anchor Plate with Damper
13 Supplementary Support
14 Wall Strap

DuraChimney planning installationPlanning Your Installation:

The following recommendations are a general guideline to assist in the layout and selection of the chimney components needed for your installation. Always follow Duravent Installation instructions enclosed with the cap or support box before installing your chimney system. Installation instructions can be viewed online at www. duravent.com, under catalogs and instructions.

  • Measure the diameter of the fireplace flue outlet. An improperly sized chimney results in poor draft and excessive creosote formation.
  • Select the chimney with the same size diameter as the fireplace flue outlet. Refer to the chimney sizing chart in the back of this catalog for masonry fireplaces.
  • Install the chimney in an enclosed chase.
  • If possible, avoid offsets. A straight vertical installation is more efficient and less likely to develop creosote. If an offset is required to avoid rafters or other obstructions, measure the horizontal distance required and the vertical height available. Both 15° and 30° elbows are available. Elbows greater than 30° are not allowed in the United States. Two offset (four elbows) in a single installation is permitted. Refer to the offset chart in the back section of this catalog. At least one Elbow Strap is required. Elbow Straps ensure adequate support.
  • Determine the minimum chimney height above the roof line. Building codes require a minimum of 3′ above the roof penetration and at least 2′ higher than any portion of a building within 10′. See figure 1. The termination cap is installed above that point.
  • Chase Top Flashing is available. A pitched roof flashing can be locally made, if required. A storm collar is required for all installations using a flashing.
  • Determine the total length of chimney required for the installation. To calculate the installed per length of 10″-16″ DuraChimney II pipe, subtract 1″ per joint. Minimum recommended chimney height, at sea level of straight vertical chimney, is 10′ to 15′ above the fireplace outlet. Higher elevations, or the use of elbows, will require approximately 30% to 60% more height to provide for an adequate draft.
  • For a UL approved shroud, see the DuraChimney II Shrouds Installation Instructions (L181). View online at www.duravent. com, under catalogs and instructions.
  • Be fire safe. Maintain at least 2″ clearance to combustibles. Follow local building codes and have your chimney inspected by a certified professional.

Product Resources

Catalogs

Bulletins

Sales Sheets

FAQ

How do I build a 10-inch DuraChimney II kit on this page?

There is no base price; the chimney is priced from what you select. The 10-inch pipe length row is required, so choose at least one 12, 18, 36 or 48 inch section with quantities, then add 15 or 30 degree elbows and the components you need from the Build Your Chimney Kit row: anchor plate, firestop spacer, shields, chase top flashing, storm collar and cap, each priced on the selector.

Which fireplaces take a 10-inch DuraChimney II chimney?

Fireplaces burning wood, oil, coal or gas whose flue collar is 10 inches and whose manual names DuraChimney II as an approved chimney. It is a unitized, double-wall, air-cooled chimney listed to UL 103 and ULC S604 for continuous 1000 F operation, with a 430 stainless inner wall and galvanized outer wall (a stainless outer is available through customer service).

What is the Anchor Plate with Damper option?

The plain Anchor Plate is the starting piece that mounts on the fireplace top; the damper version adds a chimney damper at the base. DuraVent’s instructions warn that a damper anchor plate may only be used where the fireplace manufacturer permits it, so check that manual first. Either plate is fastened to the fireplace top with four sheet metal screws before the first section twist-locks on.

How much 10-inch pipe do I need, and how is it supported?

Measure from the anchor plate to the cap, subtract 1 inch per joint, and plan on 10 to 15 feet minimum above the fireplace outlet plus the code rule of 3 feet above the roof and 2 feet above anything within 10 feet. Add a Wall Strap every 8 feet, a Supplementary Support once the chimney exceeds 50 feet (each supports 25 feet) and a Stabilizer to center the pipe in the chase.

What are the European Copper King and Bishop adapters?

They are adapters that let DuraChimney II terminate in a European Copper decorative chimney pot instead of the standard cap; DuraVent publishes separate copper-pot instructions, linked in the Instructions tab. Choose the adapter that matches the pot model, and remember the storm collar and a listed cap arrangement are still required when a flashing is used.

Does this chimney need a chase and firestops?

Yes. DuraVent installs DuraChimney II inside an enclosed chase with 2 inches of air space to combustibles, a Firestop Spacer at every floor or ceiling level, an Attic Insulation Shield through an attic, a Roof Radiation Shield where it exits and a Chase Top Flashing with a 1/2-inch air gap. Compare the other DuraChimney II diameters if your collar is not 10 inches.

Shipping / Freight / Return Info

Same-Day / 24 hour shipping

Same-Day/24 hour shipping - If we have the product in stock, we can ship same day if ordered before 12pm Monday - Friday (CST).

Freight Claims Policy

Please follow these very important steps when it comes to Freight Items that are damaged or missing
  • Open and inspect the order while the delivery driver is present. If delivery driver does not provide sufficient time to do so, please notate the delivery receipt.
  • By signing the delivery receipt without noting any damage or missing items, you confirm that your order arrived complete and in excellent condition.
  • Record any damage or missing pieces directly on the delivery receipt.
  • Do not discard damaged item(s) or any original packaging. For severe damage, write “Refused due to damage” on the delivery receipt and contact us immediately.
  • Report any damage within two business days, including delivery details and photos showing the issue
  • Damaged item(s) must be returned within 30 days. Failure to return them will result in a charge to the original payment method.

Return Merchandise Authorization Policy

Please follow these very important steps when Returning Items. Contact our team.
  • Submit your return request within 30 days of delivery.
  • You will receive an email within 1-2 business days confirming whether your return request has been approved or denied.
  • Please also note that a 20% restocking fee may apply to approved returns
  • If approved, you will receive an itemized Return Authorization, return shipping labels (if requested), and detailed instructions within 1–2 business days
  • From the date this email is received, you will have 14 days to return the product.
  • Once our distributor receives and inspects the returned item(s), your refund will be issued within 1–2 weeks
  • Items returned outside of this process or time frame are not eligible for a refund.

Customer Reviews

Be the first to review this product

What Our Customers Say

Shop by Best Sellers

Fireplace

Get In Touch

Call or Text us for our Best Price

It's important to us to go above and beyond for our clients and make sure you make the right decision for your home.