DuraVent 16” DuraChimney II Customize your Kit

$0.00

✓ Free Shipping
✓ No Sales Tax (except WY)
✓ 100% Price Match Guarantee

DuraVent Logo

DuraVent Logo    Authorized Dealer – Full Warranty Included

Length of Chimney Pipe for 16" Diameter *

12" - 16DCA-12 (+$226.14)
18" - 16DCA-18 (+$279.54)
36" - 16DCA-36 (+$436.58)
48" - 16DCA-48 (+$453.86)

Elbow 16"

15° Elbow - 16DCA-E15 (+$618.64)
30° Elbow - 16DCA-E30 (+$436.58)

Build Your Chimney Kit

Elbow Strap 16" - 16DCA-ES (+$205.34)
Supplementary Support 16" - 16DCA-SS (+$357.43)
Wall Strap 16" - 16DCA-WS (+$313.35)
Stabilizer 16" - 16DCA-ST (+$192.46)
16" Diameter Anchor Plate - 16DCA-AP (+$618.64)
16" Anchor Plate w/ Damper - 16DCA-APD (+$1,052.19)
16" DCA FireStop Spacer - 16DCA-FS (+$114.64)
16" Diameter Attic Insulation Shield - 16DCA-IS (+$785.22)
16" Diameter Roof Radiation Shield - 16DCA-RRS (+$515.53)
16" Chase Top Flashing - 16DCA-CTF (+$756.09)
16" Chase Top Collar - 16DCA-CTC (+$500.92)
16" Diameter Storm Collar - 16DCA-SC (+$69.10)
Chimney Cap 16" - 16DCA-VC1 (+$716.12)
16" European Copper Bishop Adapter - 16DCA-ECB (+$362.15)
Snow Splitter - 6DT-SP (+$283.68)
Total options:
Order total:

DuraVent DuraChimney II 16 inch Kit Builder: choose a whole chimney on one page

The DuraVent DuraChimney II 16 inch Kit Builder is a page for choosing a complete 16 inch fireplace chimney. Build it here without visiting separate parts pages. There is no base price, just the parts you choose. DuraChimney II is DuraVent’s air cooled chimney, a double wall pipe in 8 to 16 inch sizes for fireplaces that burn wood, oil, coal, or gas. This is the largest size. It must match your fireplace’s flue collar, the opening where the chimney connects. The fireplace maker must approve DuraChimney II.

Choose at least one pipe section, 12, 18, 36, or 48 inches long, and the quantity of each. Optional fixed 15 or 30 degree elbows are sold individually. Two make a sideways shift, but no pipe can run horizontally. Add supports, shields, flashing, and a cap as needed. The chimney normally sits inside a chase, a framed box with 2 inches of air space around the pipe. Flashing covers the chase top while leaving ventilation gaps. Need pipe separately? See the DuraVent DuraChimney II 8 to 16 inch Chimney Pipe. The DuraVent DuraChimney II 16 inch Kit Builder ships free from My Cozy Outdoors with No Sales Tax (except WY) and the full manufacturer warranty.

Details

SKU: 16DCA-12

Applications

DuraChimney II is a double-wall, air-cooled chimney system for use with masonry fireplaces which burn wood, oil, coal, or gas.

Materials and Construction

.016″ 430 stainless steel inner wall and .021″ galvanized steel outer wall. For stainless steel outer wall, contact Customer Service.

Unitized pipe sections. No field assembly of inners and outers required.

Clearances

2″ clearance to combustibles.

Shrouds

UL Listed with Duravent shroud specifications.

Diameters

10″, 12″, 14″, and 16″

Listings

UL Listed to UL 103 and ULC S604 standards (MH7399).

Instructions

 

Typical Installation

Refer to our Typical Installation drawings to select the appropriate component parts for your installation.

DuraVent DuraChimney II

 

More Typical Installations

 

DuraVent More Typical Installations

Installation Key

1 Chimney Cap
2 Storm Collar
3 Chase Top Flashing
4 Roof Radiation Shield
5 Chimney Section
6 Elbow
7 Elbow Strap
8 Stabilizer
9 Firestop
10 Attic Insulation Shield
11 Anchor Plate
12 Anchor Plate with Damper
13 Supplementary Support
14 Wall Strap

DuraChimney planning installationPlanning Your Installation:

The following recommendations are a general guideline to assist in the layout and selection of the chimney components needed for your installation. Always follow Duravent Installation instructions enclosed with the cap or support box before installing your chimney system. Installation instructions can be viewed online at www. duravent.com, under catalogs and instructions.

  • Measure the diameter of the fireplace flue outlet. An improperly sized chimney results in poor draft and excessive creosote formation.
  • Select the chimney with the same size diameter as the fireplace flue outlet. Refer to the chimney sizing chart in the back of this catalog for masonry fireplaces.
  • Install the chimney in an enclosed chase.
  • If possible, avoid offsets. A straight vertical installation is more efficient and less likely to develop creosote. If an offset is required to avoid rafters or other obstructions, measure the horizontal distance required and the vertical height available. Both 15° and 30° elbows are available. Elbows greater than 30° are not allowed in the United States. Two offset (four elbows) in a single installation is permitted. Refer to the offset chart in the back section of this catalog. At least one Elbow Strap is required. Elbow Straps ensure adequate support.
  • Determine the minimum chimney height above the roof line. Building codes require a minimum of 3′ above the roof penetration and at least 2′ higher than any portion of a building within 10′. See figure 1. The termination cap is installed above that point.
  • Chase Top Flashing is available. A pitched roof flashing can be locally made, if required. A storm collar is required for all installations using a flashing.
  • Determine the total length of chimney required for the installation. To calculate the installed per length of 10″-16″ DuraChimney II pipe, subtract 1″ per joint. Minimum recommended chimney height, at sea level of straight vertical chimney, is 10′ to 15′ above the fireplace outlet. Higher elevations, or the use of elbows, will require approximately 30% to 60% more height to provide for an adequate draft.
  • For a UL approved shroud, see the DuraChimney II Shrouds Installation Instructions (L181). View online at www.duravent. com, under catalogs and instructions.
  • Be fire safe. Maintain at least 2″ clearance to combustibles. Follow local building codes and have your chimney inspected by a certified professional.

Product Resources

Catalogs

Bulletins

Sales Sheets

FAQ

How does the 16-inch DuraChimney II Customize your Kit page work?

The listing has no base price; you choose the parts and the selector totals them. The 16-inch Length of Chimney Pipe row is required (12, 18, 36 or 48 inch sections, any quantity), the Elbow row adds 15 or 30 degree offsets, and the Build Your Chimney Kit row holds the anchor plates, firestop spacer, shields, chase top flashing and collar, storm collar, cap, Bishop copper adapter and snow splitter.

What kind of fireplace uses a 16-inch DuraChimney II?

The largest wood, oil, coal or gas fireplaces with a 16-inch flue collar whose manual names DuraChimney II as an approved chimney. It is the biggest DuraChimney II diameter, a unitized double-wall air-cooled system listed to UL 103 and ULC S604 and rated for continuous 1000 F flue gas, with a 430 stainless inner and galvanized outer wall.

How is a tall 16-inch chimney supported?

Use a Wall Strap every 8 feet, a Supplementary Support once the total height passes 50 feet (each support carries 25 feet of chimney) and a Stabilizer clamped to the pipe to keep it centered in the chase. The Anchor Plate carries the base, and the Elbow Strap supports any offset. Sections twist-lock together, so screws are not normally required.

How much pipe should I order?

Measure from the anchor plate to the top, subtract 1 inch per joint, and keep to DuraVent’s minimum of 10 to 15 feet of chimney above the fireplace outlet, adding 30 to 60 percent at altitude or with elbows. The cap must end at least 3 feet above the roof penetration and 2 feet higher than any part of the building within 10 feet.

Can I use a chimney-top damper or a copper pot on this size?

Both are on the page: the Anchor Plate with Damper, which DuraVent says to use only where the fireplace manufacturer permits, and the European Copper Bishop Adapter for a decorative copper pot termination (the King adapter is not offered in 16 inch). The copper-pot instructions are linked in the Instructions tab. Smaller collars are covered in the DuraChimney II category.

What clearance and firestopping apply?

Keep 2 inches of air space to combustibles and run the chimney in an enclosed chase. Fit a Firestop Spacer at every floor and ceiling, an Attic Insulation Shield through an attic, a Roof Radiation Shield where the chimney exits the chase, and the Chase Top Flashing with a 1/2-inch air gap, then the Storm Collar and Chimney Cap. Follow local codes and have the installation inspected.

Shipping / Freight / Return Info

Same-Day / 24 hour shipping

Same-Day/24 hour shipping - If we have the product in stock, we can ship same day if ordered before 12pm Monday - Friday (CST).

Freight Claims Policy

Please follow these very important steps when it comes to Freight Items that are damaged or missing
  • Open and inspect the order while the delivery driver is present. If delivery driver does not provide sufficient time to do so, please notate the delivery receipt.
  • By signing the delivery receipt without noting any damage or missing items, you confirm that your order arrived complete and in excellent condition.
  • Record any damage or missing pieces directly on the delivery receipt.
  • Do not discard damaged item(s) or any original packaging. For severe damage, write “Refused due to damage” on the delivery receipt and contact us immediately.
  • Report any damage within two business days, including delivery details and photos showing the issue
  • Damaged item(s) must be returned within 30 days. Failure to return them will result in a charge to the original payment method.

Return Merchandise Authorization Policy

Please follow these very important steps when Returning Items. Contact our team.
  • Submit your return request within 30 days of delivery.
  • You will receive an email within 1-2 business days confirming whether your return request has been approved or denied.
  • Please also note that a 20% restocking fee may apply to approved returns
  • If approved, you will receive an itemized Return Authorization, return shipping labels (if requested), and detailed instructions within 1–2 business days
  • From the date this email is received, you will have 14 days to return the product.
  • Once our distributor receives and inspects the returned item(s), your refund will be issued within 1–2 weeks
  • Items returned outside of this process or time frame are not eligible for a refund.

Customer Reviews

Be the first to review this product

What Our Customers Say

Shop by Best Sellers

Fireplace

Get In Touch

Call or Text us for our Best Price

It's important to us to go above and beyond for our clients and make sure you make the right decision for your home.