Detroit Radiant BAH Series Medium-Wave Electric Infrared Space Heater – BAH

$355.50

✓ Free Shipping
✓ No Sales Tax (except WY)

✓ 100% Price Match Guarantee

Detroit Radiant Logo BlackAuthorized Dealer – Full Warranty Included

Size & Output *

18" – 500 W - BAH-18-A-05 (+$0)
25" – 1,000 W - BAH-25 (+$20.70)
35" – 1,750 W - BAH-35 (+$75.60)
45" – 2,500 W - BAH-45 (+$115.20)
60" – 3,000 W - BAH-60 (3.0 kW) (+$261)
60" – 4,000 W - BAH-60 (4.0 kW) (+$261)

Accessories

Detroit Radiant Re-Verber-Ray MB-1
MB-1 Mounting Bracket Pair (180° adjustable) - MB-1: Wall or ceiling bracket pair with 180 degrees of tilt (+$51.30)

Controls

Detroit Radiant Re-Verber-Ray SWPD60
60-Minute Twist Timer - SWPD60: Twist timer, up to 60 minutes (+$66.60)
Detroit Radiant Re-Verber-Ray SWPD-4H
4-Hour Twist Timer - SWPD-4H: Twist timer, up to 4 hours (+$66.60)
Detroit Radiant Re-Verber-Ray WEP-TS
Weatherproof Timer Enclosure Package - WEP-TS: Lockable outdoor box with a 4-hour timer and on/off switch (+$127.80)
Detroit Radiant Re-Verber-Ray TH-115
Rain-Tight Thermostat, Single Stage - TH-115: Weatherproof, 40 to 100 F, single stage (+$99)
Detroit Radiant Re-Verber-Ray TH-115-60B
Rain-Tight Thermostat, Single Stage, Remote Bulb - TH-115-60B: Weatherproof, 40 to 100 F, with a 60 inch remote sensing bulb (+$135)
Detroit Radiant Re-Verber-Ray TH-ET5
Basic Dial Thermostat - TH-ET5: Simple dial, 35 to 75 F (+$56.70)
Detroit Radiant Re-Verber-Ray TH-PTLV
7-Day Programmable Thermostat, 120 V Line Voltage - TH-PTLV: 7-day programmable; 120 V heaters only (+$158.40)
Detroit Radiant Re-Verber-Ray TH-1A66
Line-Voltage Heater Thermostat (up to 277 V) - TH-1A66: Wires straight to the heater, up to 277 V and 5,000 W (+$39.60)
Detroit Radiant Re-Verber-Ray MWC-16
Variable Heat Controller, 120 V / 1,600 W - MWC-16: Dial the heat up or down; 120 V heaters up to 1,600 W (+$157.50)
Detroit Radiant Re-Verber-Ray MWC-32
Variable Heat Controller, 208/240 V / 3,200 W - MWC-32: Dial the heat up or down; 208/240 V heaters up to 3,200 W (+$172.80)
Detroit Radiant Re-Verber-Ray SMWC-18
Variable Heat Controller, 120 V / 1,800 W (SMWC) - SMWC-18: Dial the heat up or down; 120 V heaters up to 1,800 W (+$437.40)
Detroit Radiant Re-Verber-Ray SMWC-36A
Variable Heat Controller, 208/240 V / 3,600 W (SMWC) - SMWC-36A: Dial the heat up or down; 208/240 V heaters up to 3,600 W (+$837)
Detroit Radiant Re-Verber-Ray TH-BR12
Digital Thermostat, Non-Programmable - TH-BR12: Digital, non programmable, 45 to 90 F; 24 V, needs a transformer (+$79.20)
Detroit Radiant Re-Verber-Ray TH-BR22
Digital Thermostat, Programmable - TH-BR22: Digital, programmable, 45 to 90 F; 24 V, needs a transformer (+$100.80)
Detroit Radiant Re-Verber-Ray TH-BR42
Digital Thermostat, Programmable + Remote Sensing - TH-BR42: Programmable with remote sensor port; 24 V, needs a transformer (+$180)
Detroit Radiant Re-Verber-Ray TH-1F86WF
Wi-Fi Programmable Thermostat - TH-1F86WF: Wi-Fi, set from your phone; 24 V, needs a transformer (+$262.80)
Detroit Radiant Re-Verber-Ray TH-B205WF
Wi-Fi Programmable Thermostat (Braeburn) - TH-B205WF: Wi-Fi, set from your phone; 24 V, needs a transformer (+$189)
Detroit Radiant Re-Verber-Ray TH-ENASC
NEMA 4X Wi-Fi Thermostat with App Scheduling - TH-ENASC: Outdoor rated Wi-Fi with app scheduling; 24 V, needs a transformer (+$387)
Detroit Radiant Re-Verber-Ray TH-B500WL
Wireless Thermostat Kit - TH-B500WL: Wireless thermostat kit, no wire to the heater; 24 V (+$280.80)
Detroit Radiant Re-Verber-Ray MTGRD
Locking Thermostat Guard, Metal - MTGRD: Metal cover with key, stops tampering (+$45)
Detroit Radiant Re-Verber-Ray F29GRD
Locking Thermostat Guard, Clear - F29GRD: Clear cover with key, stops tampering (+$46.80)

Contactors & Transformers

Detroit Radiant Re-Verber-Ray CE-40-24
Contactor Panel, 40 A, 24 V Coil - CE-40-24: 40 A switching box for a 24 V thermostat or timer; needs a 24 V transformer (+$174.60)
Detroit Radiant Re-Verber-Ray CE-60-24
Contactor Panel, 60 A, 24 V Coil - CE-60-24: 60 A switching box for a 24 V thermostat or timer; needs a 24 V transformer (+$288)
Detroit Radiant Re-Verber-Ray 4000-01V
40 VA Transformer, 120 V to 24 V - 4000-01V: 120 V to 24 V; runs up to 2 DSC heaters or one thermostat (+$52.20)
Detroit Radiant Re-Verber-Ray 4000-01V-277
40 VA Transformer, 277 V to 24 V - 4000-01V-277: 277 V to 24 V for 277/480 V buildings (+$45)
Detroit Radiant Re-Verber-Ray 5000-01V
40 VA Transformer, 208/240 V to 24 V - 5000-01V: 208/240 V to 24 V (+$85.50)
Product price: $355.50
Total options:
Order total:

Detroit Radiant BAH Electric Space Heater: quick heat for commercial spaces only

The Detroit Radiant BAH Electric Space Heater is a commercial electric heater that gives off heat within seconds of switching on. Radiant heat warms people and surfaces directly, like sunshine, instead of warming the air. A single quartz element, the part that produces heat, sits inside a black steel housing. It gives off almost no visible light and needs no venting. It suits spots such as ticket booths, work stations and loading docks where gas heat or a vent is not practical. The BAH is for commercial and industrial spaces only; Detroit Radiant does not approve it for a home, mobile home, RV, camper or tent.

Choose from five lengths, from 18 to 60 inches, with outputs from 500 to 4,000 watts. Then choose a voltage offered for that size. Adjustable mounting brackets come in the box for wall or ceiling mounting. No control is included. An electrician wires it to a separately supplied switch, timer, thermostat or variable heat controller. Shopping for a home patio? See the Detroit Radiant DSS Electric Patio Heater. The Detroit Radiant BAH Electric Space Heater ships free from My Cozy Outdoors with No Sales Tax (except WY) and the full manufacturer warranty.

Weight 3.6 kg
Dimensions 45.7 × 17.1 × 16.3 cm

Features

  • Pollution free, no venting required
  • Produces virtually instant heat
  • Clean and quiet operation
  • Five lengths from 18 to 60 inches, 500 to 4,000 watts, at 120, 208, 240, 480 or 575 volts
  • Ideal for low output, low clearance spots where gas or ventilation is not practical
  • Commercial and industrial use only. Not for homes, mobile homes, RVs, campers or tents.

Applications

Application by Industry

Use radiant heat in a variety of hard to heat applications. Infrared heats people, floors, walls and other surfaces directly without heating the air first, which is why it works where forced air fails. Tap an industry to see how Detroit Radiant heaters are used there.

Detroit Radiant Re-Verber-Ray infrared heaters in a agriculture application
Detroit Radiant Re-Verber-Ray infrared heaters in a agriculture application
Detroit Radiant Re-Verber-Ray infrared heaters in a agriculture application
Detroit Radiant Re-Verber-Ray infrared heaters in a agriculture application
Detroit Radiant Re-Verber-Ray infrared heaters in a agriculture application
Detroit Radiant Re-Verber-Ray infrared heaters in a agriculture application

Agriculture

Low intensity radiant tube brooders and high intensity brooders.

Infrared heaters are widely used in swine, poultry, brooder and dairy barns because they have a long record of proven results. Two stage heaters add efficiency and several benefits: lower running costs, less on and off cycling, more fuel saved, the ability to change the heat output, and better animal comfort. The result is better animal performance, less fuel burned and a longer heater life.

  • Save 20 to 50 percent on the fuel bill with radiant tube heat compared with other heating appliances
  • Cut annual maintenance by up to 90 percent
  • Optional two stage operation for better comfort
  • Quiet, clean operation
Detroit Radiant Re-Verber-Ray infrared heaters in a aircraft hangars application
Detroit Radiant Re-Verber-Ray infrared heaters in a aircraft hangars application
Detroit Radiant Re-Verber-Ray infrared heaters in a aircraft hangars application
Detroit Radiant Re-Verber-Ray infrared heaters in a aircraft hangars application

Aircraft Hangars

Heat large, hard to heat areas.

Gas fired infrared heaters heat efficiently because they warm exactly what needs to be warm: people, floors, walls and other surfaces, instead of the air. That suits hangars with huge air volumes or lots of air movement, where warm air heating is wasted because it must first heat all the air, which rises before anything else does.

Equipment selection: high BTU tube heaters or high intensity models are made for high mounting spots like hangars. Two stage heaters recover the heat lost through the big doors, then cycle less during normal operation. Most of the heat should be concentrated near the main door with burner boxes or extra heaters. ANSI/NFPA 409 calls for the heater to sit at least 10 feet above the highest wing surface of any aircraft stored inside.

Commonly used products

  • HLV Series engineered vacuum systems
  • REV Series two stage low intensity
  • HL3 Series two stage low intensity
  • DX3L Series single stage low intensity
  • DR Series high intensity
Detroit Radiant Re-Verber-Ray infrared heaters in a automotive application
Detroit Radiant Re-Verber-Ray infrared heaters in a automotive application
Detroit Radiant Re-Verber-Ray infrared heaters in a automotive application
Detroit Radiant Re-Verber-Ray infrared heaters in a automotive application
Detroit Radiant Re-Verber-Ray infrared heaters in a automotive application
Detroit Radiant Re-Verber-Ray infrared heaters in a automotive application

Automotive

Efficiently heat open door service areas.

Most service garages and vehicle maintenance shops have a lot of open door area for their size, and cold vehicles keep rolling in. That makes infrared the economical way to heat the space. When placing heaters, keep them away from overhead doors and vehicle lifts, keep the published clearances from hose reels and exhaust collection systems, and never put a heater inside a paint booth. In smaller areas where tube heaters are not practical, a forced air unit heater can fill in.

Detroit Radiant recommends low intensity tube heaters with outside air supplied to each heater where degreasers, parts washers or rust proofing are used, plus mechanical ventilation at floor level, since most chemical fumes are heavier than air. Most centers use 75,000 to 150,000 BTU tube heaters in a perimeter layout, with extra units or burner boxes stacked at the door areas.

Commonly used products

  • REV Series two stage low intensity
  • HL3 Series two stage low intensity
  • DX3L Series single stage low intensity
  • MP3 Series modulating low intensity
  • DR Series high intensity
  • FA and UH Series separated combustion unit heaters
Detroit Radiant Re-Verber-Ray infrared heaters in a car washes application
Detroit Radiant Re-Verber-Ray infrared heaters in a car washes application
Detroit Radiant Re-Verber-Ray infrared heaters in a car washes application
Detroit Radiant Re-Verber-Ray infrared heaters in a car washes application

Car Washes

Save energy while heating harsh environments.

Short tube heaters with high BTU ratings, or small to mid size high intensity heaters, are the efficient choices for a car wash. Most car wash heating systems are designed to protect against freezing and to spot heat employees, so the heaters are best placed at the ends of the tunnel. Millivolt controls are the usual pick for equipment rooms, if shielded from the wind, so freeze protection keeps working during a power outage.

Stainless steel, silicone sealant, waterproof controls and electrical attachments are recommended, and two stage operation adds further energy savings.

Commonly used products

  • Stainless steel low intensity tube heaters
  • DR Series high intensity
Detroit Radiant Re-Verber-Ray infrared heaters in a cng facilities application
Detroit Radiant Re-Verber-Ray infrared heaters in a cng facilities application
Detroit Radiant Re-Verber-Ray infrared heaters in a cng facilities application
Detroit Radiant Re-Verber-Ray infrared heaters in a cng facilities application
Detroit Radiant Re-Verber-Ray infrared heaters in a cng facilities application

CNG Facilities

Heating vehicle maintenance facilities.

Natural gas is an affordable, abundant fuel for fleets, and Detroit Radiant has the experience to heat compressed natural gas (CNG) vehicle maintenance facilities. The company offers a range of options and can usually turn around concept drawings within a few days.

CNG shops must comply with special requirements such as NFPA 30A, which says the heater surface temperature must not exceed 750 degrees F. Detroit Radiant's CSA design certified heaters meet the construction criteria the code requires. When the space needs more burners than will fit, the engineered HLV vacuum system can be used in the design.

Commonly used products

  • CL3 Series two stage low intensity
  • CX3 Series single stage low intensity
  • HLV Series engineered vacuum systems
Detroit Radiant Re-Verber-Ray infrared heaters in a military application
Detroit Radiant Re-Verber-Ray infrared heaters in a military application
Detroit Radiant Re-Verber-Ray infrared heaters in a military application
Detroit Radiant Re-Verber-Ray infrared heaters in a military application

Military

Products and expertise for the Navy, Air Force, Army, Marines and Coast Guard.

Detroit Radiant's product range and military experience have been used in a wide variety of military applications, including projects for the United States Navy, Air Force, Army, Marines and Coast Guard.

Commonly used products

  • HLV Series engineered vacuum systems
  • MP3 Series modulating low intensity
  • REV Series two stage low intensity
  • HL3 Series two stage low intensity
  • DX3L Series single stage low intensity
Detroit Radiant Re-Verber-Ray infrared heaters in a municipal application
Detroit Radiant Re-Verber-Ray infrared heaters in a municipal application
Detroit Radiant Re-Verber-Ray infrared heaters in a municipal application

Municipal

Fleet heating for fleet, transit and police facilities.

Detroit Radiant offers a wide selection of infrared heating products for municipal fleet facilities: fleet maintenance garages, transit facilities and garages, police stations and more.

Commonly used products

  • CL3 Series two stage low intensity
  • CX3 Series single stage low intensity
  • HLV Series engineered vacuum systems
  • REV Series two stage low intensity
  • HL3 Series two stage low intensity
  • DX3L Series single stage low intensity
  • DR Series high intensity
Detroit Radiant Re-Verber-Ray infrared heaters in a outdoor application
Detroit Radiant Re-Verber-Ray infrared heaters in a outdoor application
Detroit Radiant Re-Verber-Ray infrared heaters in a outdoor application
Detroit Radiant Re-Verber-Ray infrared heaters in a outdoor application
Detroit Radiant Re-Verber-Ray infrared heaters in a outdoor application
Detroit Radiant Re-Verber-Ray infrared heaters in a outdoor application
Detroit Radiant Re-Verber-Ray infrared heaters in a outdoor application
Detroit Radiant Re-Verber-Ray infrared heaters in a outdoor application

Outdoor

Gently warm people and furnishings, not the air.

Whether you want to extend the outdoor season, heat a designated smoking area or add room for peak crowds, Detroit Radiant's range has an outdoor heater to fit.

  • Air movement: wind, even a light breeze, is the biggest variable in outdoor comfort. Barriers such as wind curtains are highly recommended wherever possible, but always keep the clearances to combustibles.
  • Mounting heights: outdoor and spot heating usually means mounting the heater lower, closer to the people. A lower mount covers less area but gives a more focused heat pattern, so the final height may need adjusting to get the result you want.
  • Your expectations: there is rarely a one size fits all answer. Maximum comfort in extreme conditions takes more heaters; taking the chill off a smoking area for a few minutes takes fewer.

Commonly used products

Detroit Radiant Re-Verber-Ray infrared heaters in a spot heating application
Detroit Radiant Re-Verber-Ray infrared heaters in a spot heating application
Detroit Radiant Re-Verber-Ray infrared heaters in a spot heating application
Detroit Radiant Re-Verber-Ray infrared heaters in a spot heating application

Spot Heating

Heating only a portion of a building? Detroit Radiant offers great options.

When only part of a building needs heat, consider spot heating. Both high intensity infrared heaters and low intensity tube heaters suit it. Tube heaters are usually placed in a U shape for spot heating: the U puts the hottest tube next to the coolest tube for even comfort and gives the most flexibility in placement.

High intensity heaters are usually easier to install and cheaper for spot heating. They are especially suited to buildings that are poorly insulated, loosely built, have high ceilings or lose a lot of heat per square foot.

Commonly used products

Detroit Radiant Re-Verber-Ray infrared heaters in a warehouses application
Detroit Radiant Re-Verber-Ray infrared heaters in a warehouses application
Detroit Radiant Re-Verber-Ray infrared heaters in a warehouses application
Detroit Radiant Re-Verber-Ray infrared heaters in a warehouses application

Warehouses

Strategically placed for the best coverage of the space.

Detroit Radiant offers many cost effective options for heating a warehouse. When choosing equipment, consider the warehouse type, its size, the mounting heights, the level of insulation and any other design features that affect the heater choice. Tube heaters give plenty of placement options with regard to clearances and are usually thermostat controlled.

Place warehouse heaters for the best coverage: a perimeter layout, or a series of heaters between rows of storage racks. Whatever the layout, mind the clearances to combustibles, especially above and below the heater where stacked goods are a concern. Detroit Radiant recommends warning plaques (part PLQ) to advise users of the clearances and stacking limits.

Commonly used products

  • HLV Series engineered vacuum systems
  • REV Series two stage low intensity
  • HL3 Series two stage low intensity
  • DX3L Series single stage low intensity
  • DR Series high intensity
  • ELD Series electric
  • ELX Series electric

The heaters we carry from Detroit Radiant are the outdoor and electric lines: the DSC, DSR and DSRF gas patio heaters and the ELD, ELX, DSS and BAH electric heaters. The commercial tube and high intensity lines named above are built by the same company for the other industries.

Shop All Detroit Radiant Heaters

Specifications

SKU: BAH-18-A-05, BAH-25-A-10, BAH-25-B-10, BAH-25-C-10, BAH-35-A-17, BAH-35-B-17, BAH-35-C-17, BAH-45-B-25, BAH-45-C-25, BAH-60-B-30, BAH-60-C-30, BAH-60-C-40, BAH-60-G-30, BAH-60-D-40

Not for residential use. Detroit Radiant: “BAH Series heaters are NOT for home or recreational use. DO NOT USE in the home, mobile home, RVs, tents, etc.”

Model Length Voltage Watts BTU/h Amps Weight
BAH-18-A-05 18″ 120 V 500 W 1,700 4.2 A 8 lbs
BAH-25-A-10 25″ 120 V 1,000 W 3,400 8.3 A 10 lbs
BAH-25-B-10 25″ 208 V 1,000 W 3,400 4.8 A 10 lbs
BAH-25-C-10 25″ 240 V 1,000 W 3,400 4.2 A 10 lbs
BAH-35-A-17 35″ 120 V 1,750 W 5,900 14.0 A 13 lbs
BAH-35-B-17 35″ 208 V 1,750 W 5,900 8.3 A 13 lbs
BAH-35-C-17 35″ 240 V 1,750 W 5,900 7.0 A 13 lbs
BAH-45-B-25 45″ 208 V 2,500 W 8,500 12.0 A 16 lbs
BAH-45-C-25 45″ 240 V 2,500 W 8,500 10.0 A 16 lbs
BAH-60-B-30 60″ 208 V 3,000 W 10,200 14.0 A 20 lbs
BAH-60-C-30 60″ 240 V 3,000 W 10,200 12.0 A 20 lbs
BAH-60-C-40 60″ 240 V 4,000 W 13,500 16.5 A 20 lbs
BAH-60-G-30 60″ 480 V 3,000 W 10,200 6.2 A 20 lbs
BAH-60-D-40 60″ 575 V 4,000 W 13,500 7.0 A 20 lbs
Specification Value
Element 0.5″ drawn quartz with high temperature ceramic end caps, coiled tungsten; replacement QT elements available for every model
Light Mild white medium wave; very little visible light
Housing Black coated steel chassis, 6.75″ W x 6.4″ H; length per model
Mounting 0° to 20° adjustable brackets included; chain, wall or ceiling; optional MB-1 bracket pair gives 180° of adjustment
Recommended mounting height 25″: 7 to 9 ft · 35″: 8 to 10 ft · 45″: 9 to 11 ft · 60″: 10 to 12 ft
Recommended spacing 25″: 3 to 9 ft · 35″: 4 to 11 ft · 45″: 5 to 13 ft · 60″: 6 to 15 ft
Clearances to combustibles (0° to 20°) 18″ sides, 24″ ends, 12″ top, 24″ below
Controls Field supplied: switch, timer, thermostat or variable heat controller; contactor panel for 24 V control or when amperage exceeds the control rating
Shipping 60″ models ship truckline only
Certification ETL Listed, commercial and industrial only
Limited Warranty Components and replacement elements 1 year

Manuals / Catalogs

Catalogs, Brochures & Data Sheets

BAH Series Brochure

BAH Series Submittal / Engineering Specifications

BAH Series Application Chart

Electric Heater Design Guide

Electric Heater Packing List

Controls Packing List

Manuals

BAH Series Installation, Operation, Parts and Maintenance Manual

FAQ

Can I use the BAH at home?

No. Detroit Radiant is explicit: the BAH is not for home or recreational use, and must not be used in a house, mobile home, RV, camper or tent. It is ETL listed for commercial and industrial use only. For a home patio see the Detroit Radiant DSS, ELD or ELX heaters, which are listed for outdoor residential use.

Which size and voltage?

Pick the length by the spot it must warm and the watts by how cold it gets: 18 inches and 500 watts for a small booth up to 60 inches and 3,000 or 4,000 watts for a dock door. The voltage must match the circuit an electrician will wire it to; each length is built for specific voltages, which is why the Voltage list changes with the size you pick.

Where is it used?

Loading docks, guard shacks, ticket booths, work stations, shop offices and entrances: low output spots with tight clearances where a gas heater or a vent is not practical. Detroit Radiant’s design guide gives recommended mounting heights of 7 to 9 feet for the 25 inch up to 10 to 12 feet for the 60 inch, spaced 3 to 15 feet apart depending on size.

What are the clearances?

Level or tilted up to 20 degrees, keep 18 inches to the sides, 24 inches at the ends, 12 inches above and 24 inches below combustibles. The manual and the label on the heater always take precedence.

How is it mounted and controlled?

The heater hangs from chains or mounts to a wall or ceiling with the adjustable brackets in the box; the optional MB-1 bracket pair adds a full 180 degrees of adjustment. No control is included: an electrician wires it to a switch, timer, thermostat or one of the MWC or SMWC variable heat controllers on the Controls selector, with a contactor when the load is more than the control can switch.

Can I replace the element?

Yes. Every model has a matching QT replacement quartz element, listed on the Accessories selector for the size you choose. Components and elements carry a one year limited warranty. The 60 inch models ship by truck only.

Customer Reviews

Be the first to review this product

What Our Customers Say

Shop by Best Sellers

Fireplace

Get In Touch

Call or Text us for our Best Price

It's important to us to go above and beyond for our clients and make sure you make the right decision for your home.