DuraVent DuraChimney II 8 inch 15 Degree Elbow Kit: a small sideways step around a rafter or joist

The DuraVent DuraChimney II 8 inch 15 Degree Elbow Kit is a pair of angled chimney fittings with a support strap. The two elbows move the chimney sideways around a rafter or joist, then point it straight up again. This sideways section is called an offset. Both elbows have a fixed 15 degree bend, so you cannot adjust their angle. Each pipe length in the offset needs a strap of its own. The kit includes one strap, so a longer offset with more pipe sections needs extra straps. A chimney can have no more than two offsets.

This kit fits only the 8 inch DuraChimney II family, which uses twist lock joints. DuraChimney II is DuraVent’s air cooled chimney, a double wall pipe in 8 to 16 inch sizes for fireplaces that burn wood, oil, coal, or gas. Its parts cannot be modified or combined with DuraTech, DuraPlus, or another brand’s chimney. Need a bigger sideways step? See the DuraVent DuraChimney II 8 inch 30 Degree Elbow Kit. The DuraVent DuraChimney II 8 inch 15 Degree Elbow Kit ships free from My Cozy Outdoors with No Sales Tax (except WY) and the full manufacturer warranty.

Details

SKU: 8DCA-E15K

Applications

DuraChimney II is a double-wall, air-cooled chimney system for use with masonry fireplaces which burn wood, oil, coal, or gas.

Materials and Construction

.016″ 430 stainless steel inner wall and .021″ galvanized steel outer wall. For stainless steel outer wall, contact Customer Service.

Unitized pipe sections. No field assembly of inners and outers required.

Clearances

2″ clearance to combustibles.

Shrouds

UL Listed with Duravent shroud specifications.

Diameters

8″

Listings

UL Listed to UL 103 and ULC S604 standards (MH7399).

Instructions

 

Typical Installation

Refer to our Typical Installation drawings to select the appropriate component parts for your installation.

DuraVent DuraChimney II

 

More Typical Installations

 

DuraVent More Typical Installations

Installation Key

1 Chimney Cap
2 Storm Collar
3 Chase Top Flashing
4 Roof Radiation Shield
5 Chimney Section
6 Elbow
7 Elbow Strap
8 Stabilizer
9 Firestop
10 Attic Insulation Shield
11 Anchor Plate
12 Anchor Plate with Damper
13 Supplementary Support
14 Wall Strap

DuraChimney planning installationPlanning Your Installation:

The following recommendations are a general guideline to assist in the layout and selection of the chimney components needed for your installation. Always follow Duravent Installation instructions enclosed with the cap or support box before installing your chimney system. Installation instructions can be viewed online at www. duravent.com, under catalogs and instructions.

  • Measure the diameter of the fireplace flue outlet. An improperly sized chimney results in poor draft and excessive creosote formation.
  • Select the chimney with the same size diameter as the fireplace flue outlet. Refer to the chimney sizing chart in the back of this catalog for masonry fireplaces.
  • Install the chimney in an enclosed chase.
  • If possible, avoid offsets. A straight vertical installation is more efficient and less likely to develop creosote. If an offset is required to avoid rafters or other obstructions, measure the horizontal distance required and the vertical height available. Both 15° and 30° elbows are available. Elbows greater than 30° are not allowed in the United States. Two offset (four elbows) in a single installation is permitted. Refer to the offset chart in the back section of this catalog. At least one Elbow Strap is required. Elbow Straps ensure adequate support.
  • Determine the minimum chimney height above the roof line. Building codes require a minimum of 3′ above the roof penetration and at least 2′ higher than any portion of a building within 10′. See figure 1. The termination cap is installed above that point.
  • Chase Top Flashing is available. A pitched roof flashing can be locally made, if required. A storm collar is required for all installations using a flashing.
  • Determine the total length of chimney required for the installation. To calculate the installed per length of 10″-16″ DuraChimney II pipe, subtract 1″ per joint. Minimum recommended chimney height, at sea level of straight vertical chimney, is 10′ to 15′ above the fireplace outlet. Higher elevations, or the use of elbows, will require approximately 30% to 60% more height to provide for an adequate draft.
  • For a UL approved shroud, see the DuraChimney II Shrouds Installation Instructions (L181). View online at www.duravent. com, under catalogs and instructions.
  • Be fire safe. Maintain at least 2″ clearance to combustibles. Follow local building codes and have your chimney inspected by a certified professional.

Product Resources

Catalogs

Bulletins

Sales Sheets

FAQ

What is in the 15-degree Elbow Kit for 8-inch DuraChimney II?

Two 15-degree elbows and one elbow strap, sized for 8-inch DuraChimney II only. The pair lets the chimney step sideways around a rafter, ridgepole or joist and then return to vertical; the strap carries the weight of the pipe above the offset so the elbows are not loaded. The elbows are fixed at 15 degrees and are not adjustable.

When should I choose the 15-degree kit instead of the 30-degree one?

Use 15 degrees when the obstruction only needs a small sideways step; it keeps the flue closer to vertical, which drafts better and collects less creosote. The 30-degree kit reaches further per foot of rise. The DuraChimney II offset chart in the catalog shows how much horizontal reach each angle gives for a given length of pipe between the elbows.

How many offsets can an 8-inch DuraChimney II have?

A maximum of two offsets, four elbows in total, and nothing steeper than 30 degrees; that is a UL 103 limit in the United States. Each offset needs at least one elbow strap, so buy a second kit or a strap for a second offset. DuraVent advises a straight vertical run wherever possible and roughly 30 to 60 percent more chimney height when elbows are used.

Are these elbows compatible with DuraTech or DuraPlus?

No. They fit the 8-inch DuraChimney II air-cooled system only, and DuraVent does not allow its chimney lines to be mixed. The elbows twist-lock onto the chimney sections like the straight pipe, so screws are not normally required, and the 2-inch clearance to combustibles applies through the offset.

Do I still need a firestop at an offset in a ceiling?

Yes. Building code and DuraVent’s instructions require a firestop at every floor or ceiling the chimney passes, offset or not, and an attic insulation shield where it crosses an attic. Plan the offset so the elbows sit clear of the framing and the straight sections pass through the firestop opening with 2 inches of air space all round.

Shipping / Freight / Return Info

Same-Day / 24 hour shipping

Same-Day/24 hour shipping - If we have the product in stock, we can ship same day if ordered before 12pm Monday - Friday (CST).

Freight Claims Policy

Please follow these very important steps when it comes to Freight Items that are damaged or missing
  • Open and inspect the order while the delivery driver is present. If delivery driver does not provide sufficient time to do so, please notate the delivery receipt.
  • By signing the delivery receipt without noting any damage or missing items, you confirm that your order arrived complete and in excellent condition.
  • Record any damage or missing pieces directly on the delivery receipt.
  • Do not discard damaged item(s) or any original packaging. For severe damage, write “Refused due to damage” on the delivery receipt and contact us immediately.
  • Report any damage within two business days, including delivery details and photos showing the issue
  • Damaged item(s) must be returned within 30 days. Failure to return them will result in a charge to the original payment method.

Return Merchandise Authorization Policy

Please follow these very important steps when Returning Items. Contact our team.
  • Submit your return request within 30 days of delivery.
  • You will receive an email within 1-2 business days confirming whether your return request has been approved or denied.
  • Please also note that a 20% restocking fee may apply to approved returns
  • If approved, you will receive an itemized Return Authorization, return shipping labels (if requested), and detailed instructions within 1–2 business days
  • From the date this email is received, you will have 14 days to return the product.
  • Once our distributor receives and inspects the returned item(s), your refund will be issued within 1–2 weeks
  • Items returned outside of this process or time frame are not eligible for a refund.

Customer Reviews

Be the first to review this product

What Our Customers Say

Shop by Best Sellers

Fireplace

Get In Touch

Call or Text us for our Best Price

It's important to us to go above and beyond for our clients and make sure you make the right decision for your home.